استاندارد های عایق
عمده استاندارهای مورد استناد جهت عایق بندی:
Standards ASTM C665
Compliance Federal Specification HH-I-521F—
– Curtain Wall and FIRESPAN Insulation as Types I and III, Class A, Category 1 (0.02 perm, tested in accordance with ASTM
E96 procedure)
– Safing Insulation as Types I and III, Class A, Category 1
– SAFB Blankets as Type I
– FS-15 Blankets as Type I
– FS-25 Blankets as Type III, Class A, Category 1
ASTM C612
Federal Specification HH-I-558B—
– Curtain Wall Insulation (all) and FIRESPAN Insulation (all) as Types 1A & 1B and 2 (0.02 perm, tested in accordance with
ASTM E96 procedure)
– Curtain Wall Insulation (CW 70, CW 90) and FIRESPAN Insulation as Types 3 and 4 (0.02 perm, tested in
accordance with ASTM E96 procedure)
– Safing Insulation as Types 1A & 1B and 2
– Sound Attenuation Fire Blankets as Type 1A
ASTM E136 (rated noncombustible as defined by NFPA Standard 220 when tested according to ASTM E136)
– THERMAFIBER Safing Insulation
– THERMAFIBER Curtain Wall Insulation
– THERMAFIBER FIRESPAN and FIRESPAN SS Insulation
– THERMAFIBER Sound Attenuation Fire Blankets
– THERMAFIBER FS-15 and FS-25 Blankets
ASTM E814 or UL 1479
– Safing Insulation used in conjunction with SMOKE SEAL Compound or with FIRECODE Compound, or other approved
material in through-penetration firestop systems.
UL 2079
– Safing Insulation used in conjunction with various fill, void or cavity materials such as sealants and caulks in construction
joint systems.
ASTM C553
– THERMAFIBER Insulations adsorb less than 1% moisture by weight and volume